CSG ship waterproof voltage transformer - Electric Power Profession Equipment Product

CSG ship waterproof voltage transformer

Favorites Email to a friend Date: 03/12/2014
Can customize, have demand ask we, customer service of connection, look forward to your incoming telegram sincerely by various the intersection of specification and type as required! Service hotline: 400-878-1700

The products are summed up:

Ship serial forms, three-phase dry voltage transformers, our company has adopted high-quality materials and advanced technologies to produce for many years, advantage such as being dampproof, safeguard and convenient, can deepen the load centre, can be used in places of power transmission and distribution such as the subway, skyscraper, airport, station, quay, enterprise and tunnel,etc.. CSG series forms, three-phase dry voltage transformers, are used mainly for exchanging 50& mdash; 60Hz, the voltage is less than various input, output voltage of different power supply place, products of 500V, link the group, take a percentage the distribution of the line group's capacity, can carry on design and manufacture meticulously according to user's request.

Service condition:

1,Ambient temperature: -15 ¡æ& mdash; +40 ¡æ
2,The height above sea level: < 1000m
3,Relative humidity: < 90%
4,The installation place has not influenced voltage transformer insulating gas steam, chemistry depositing, dust, dirt and other explosions and corrosivity mediums seriously.
5,All special service conditions not in accordance with above-mentioned regulation, should be consults and confirm by applying unit and our factory.

Technical parameter:

1,Input the voltage: Specified voltage & plusmn; 10%
2,Output voltage: Specified +5% voltage ' Empty load)
3,Efficiency: ≥ 95%
4,The wave form is distorted: It is distorted that there is no additional wave form
5,Function: Have instructions such as input voltage, output voltage, electric current,etc.
6,Protect: Flow and protect
7,But nobody on duty works for a long time continuously for a long time
8,Insulating resistance: ≥ 50MΩ
9,Electric intensity: Worker the intersection of sine and the intersection of voltage and 2000V last, have, puncture and flash and hold the phenomenon in place with a net one minute frequently
10,Overload capacity: Two times of specified electric current, maintain for one minute.

: External dimension

Type (KVA)


External dimension
Long & times; Wide & times; It is high (cm)


Install the size (cm)


The outer cover size
Long & times; Wide & times; It is high (cm)


The voltage transformer weight (kg)


CSG-10


42× 21× 42


135× 310


70× 35× 77


90


CSG-20


52× 24× 52


155× 400


70× 35× 77


180


CSG-30


55× 28× 65


165× 400


80× 40× 87


220


CSG-40


61× 30× 65


170× 400


80× 40× 87


265


CSG-50


61× 30× 65


175× 400


100× 50× 104.5


295


CSG-60


70× 32× 66


190× 450


100× 50× 104.5


370


CSG-70


70× 32× 66


190× 450


100× 50× 104.5


400


CSG-80


70× 35× 67


195× 450


100× 50× 104.5


450


CSG-100


75× 35× 68


210× 450


100× 50× 104.5


490


CSG-120


5× 35× 68


215× 450


100× 50× 104.5


520


CSG-150


85× 37× 68


230× 450


120× 65× 114.5


650


CSG-200


95× 45× 68


290× 450


120× 65× 114.5


850

< ,/TD>

CSG-250


95× 45× 83


290× 450


120× 70× 124.5


1080


CSG-300


105× 49× 95


290× 450


120× 70× 124.5


1350


: The selecting type is briefed on (CSG ship and single, three-phase dry voltage transformer)


TAG: apparatus Apparatus CSG electric Electric luxuriant Luxuriant Ship ship transformer Transformer voltage Voltage waterproof